Assessment Year | 2015 |
---|---|
Principal Product | copper wire |
NAICS | 331420: Copper Rolling, Drawing, Extruding, and Alloying |
SIC | 3351: Rolling, Drawing, and Extruding Of Copper |
Sales Range | $50 M to 100M |
# of Employees | 275 |
Plant Area |
326,000
ft2
|
Annual Production | 40,732,181
lb
|
Production Hrs. Annual | 8,400
hrs
|
Location (State) | New York |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $934,100 | 16,955,659 |
kWh
|
$0.055 |
Electricity Demand | $228,380 | 46,176 |
kW-mo/yr
|
$4.95 |
Electricity Fees | $65,107 | - |
|
- |
Fuel Oil #4 | $57,674 | 2,265 |
MMBtu
|
$25.46 |
Other Gas | $64,533 | 2,533 |
MMBtu
|
$25.48 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $79,249 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $49,220 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Other Gas Savings | Personnel Changes Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.6218: Turn off equipment when not in use | $22,610 | - |
$20,828
378,000
kWh
|
$1,782
-
kW-mo/yr
|
- | - | - | |
02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $22,134 | - |
$22,134
401,732
kWh
|
- | - | - | - | |
03 | 2.8121: Apply for tax-free status for energy purchases | $3,172 | - | - | - | - | - | $3,172 | |
04 | 2.4322: Use or replace with energy efficient substitutes | $2,751 | - |
$1,860
33,750
kWh
|
$891
-
kW-mo/yr
|
- | - | - | |
05 | 2.7224: Reduce space conditioning during non-working hours | $1,359 | - | - | - |
$1,359
-
MMBtu
|
- | - | |
06 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $17,708 | $1,340 |
$17,708
321,385
kWh
|
- | - | - | - | |
07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,620 | $805 |
$367
6,657
kWh
|
$45
-
kW-mo/yr
|
- | $900 | $308 | |
08 | 2.4133: Use most efficient type of electric motors | $7,312 | $14,040 |
$6,480
117,600
kWh
|
$832
-
kW-mo/yr
|
- | - | - | |
09 | 2.6211: Conserve energy by efficient use of vending machines | $583 | $1,743 |
$583
10,489
kWh
|
- | - | - | - | |
TOTAL RECOMMENDED | $79,249 | $17,928 |
$69,960
1,269,613
kWh
|
$3,550
-
kW-mo/yr
|
$1,359
-
MMBtu
|
$900 | $3,480 | ||
TOTAL IMPLEMENTED | $49,220 | $2,145 |
$40,763
739,792
kWh
|
$2,718
-
kW-mo/yr
|
$1,359
-
MMBtu
|
$900 | $3,480 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Other Gas Savings | Personnel Changes Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs