Assessment Year | 2013 |
---|---|
Principal Product | Low Pressure Sewer Systems and Condition Monitoring for Power Generation |
NAICS | 333911: Pump and Pumping Equipment Manufacturing |
SIC | 3561: Pumps and Pumping Equipment |
Sales Range | $50 M to 100M |
# of Employees | 150 |
Plant Area |
75,000
ft2
|
Annual Production | 100,000
pieces
|
Production Hrs. Annual | 2,601
hrs
|
Location (State) | New York |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $58,423 | 926,640 |
kWh
|
$0.063 |
Electricity Demand | $31,754 | 2,948 |
kW-mo/yr
|
$10.77 |
Electricity Fees | $7,476 | - |
|
- |
Natural Gas | $13,976 | 2,234 |
MMBtu
|
$6.26 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $8,188 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $4,192 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.8121: Apply for tax-free status for energy purchases | $1,901 | - | - | - | - | $1,901 | |
02 | 4.821: Pay bills on time to avoid late fees | $599 | - | - | - | - | $599 | |
03 | 2.7111: Reduce illumination to minimum necessary levels | $223 | - |
$223
3,537
kWh
|
- | - | - | |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,291 | $1,750 |
$2,291
36,370
kWh
|
- | - | - | |
05 | 2.6211: Conserve energy by efficient use of vending machines | $373 | $1,418 |
$373
5,921
kWh
|
- | - | - | |
06 | 2.7243: Improve air circulation with destratification fans / other methods | $1,775 | $5,400 |
$(-107.0)
(-1,720)
kWh
|
$(-12.0)
-
kW-mo/yr
|
$1,894
-
MMBtu
|
- | |
07 | 2.7314: Reduce ventilation air | $1,026 | $3,934 |
$132
2,100
kWh
|
- |
$894
-
MMBtu
|
- | |
TOTAL RECOMMENDED | $8,188 | $12,502 |
$2,912
46,208
kWh
|
$(-12.0)
-
kW-mo/yr
|
$2,788
-
MMBtu
|
$2,500 | ||
TOTAL IMPLEMENTED | $4,192 | $1,750 |
$2,291
36,370
kWh
|
- | - | $1,901 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs