Assessment Year | 2012 |
---|---|
Principal Product | Polyester Film |
NAICS | 325211: Plastics Material and Resin Manufacturing |
SIC | 2821: Plastics Materials, Synthetic Resins, and Nonvulcanizable Elastomers |
Sales Range | $10 M to 50M |
# of Employees | 53 |
Plant Area |
100,000
ft2
|
Annual Production | 9,033
ton
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | New York |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $829,095 | 13,967,617 |
kWh
|
$0.059 |
Electricity Demand | $192,858 | 21,755 |
kW-mo/yr
|
$8.86 |
Electricity Fees | $14,877 | - |
|
- |
Natural Gas | $35,033 | 4,000 |
MMBtu
|
$8.76 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $53,011 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $40,235 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.7314: Reduce ventilation air | $5,156 | $9,920 |
$335
5,678
kWh
|
$222
-
kW-mo/yr
|
$4,599
-
MMBtu
|
- | - | |
02 | 2.4321: Upgrade obsolete equipment | $206 | $669 |
$171
2,891
kWh
|
$35
-
kW-mo/yr
|
- | - | - | |
03 | 2.6211: Conserve energy by efficient use of vending machines | $124 | $395 |
$124
2,103
kWh
|
- | - | - | - | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $32,346 | $123,757 |
$19,485
330,252
kWh
|
$4,009
-
kW-mo/yr
|
- | $7,344 | $1,508 | |
05 | 2.7135: Install occupancy sensors | $955 | $4,144 |
$955
16,184
kWh
|
- | - | - | - | |
06 | 2.3212: Optimize plant power factor | $7,620 | $38,838 | - | - | - | - | $7,620 | |
07 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $4,284 | $1,655 |
$4,284
72,611
kWh
|
- | - | - | - | |
08 | 3.1161: Eliminate/reduce an operation | $2,320 | $4,530 |
$(-64.0)
(-1,080)
kWh
|
$(-160.0)
-
kW-mo/yr
|
- | $878 | $1,666 | |
TOTAL RECOMMENDED | $53,011 | $183,908 |
$25,290
428,639
kWh
|
$4,106
-
kW-mo/yr
|
$4,599
-
MMBtu
|
$8,222 | $10,794 | ||
TOTAL IMPLEMENTED | $40,235 | $135,150 |
$24,955
422,961
kWh
|
$3,884
-
kW-mo/yr
|
- | $8,222 | $3,174 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs