Assessment Year | 2011 |
---|---|
Principal Product | Manufactured Housing |
NAICS | 321991: Manufactured Home (Mobile Home) Manufacturing |
SIC | 2451: Mobile Homes |
Sales Range | $10 M to 50M |
# of Employees | 95 |
Plant Area |
182,000
ft2
|
Annual Production | 733
pieces
|
Production Hrs. Annual | 2,210
hrs
|
Location (State) | New York |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $53,550 | 845,324 |
kWh
|
$0.063 |
Electricity Demand | $18,472 | 4,650 |
kW-mo/yr
|
$3.97 |
Electricity Fees | $13,868 | - |
|
- |
Natural Gas | $41,386 | 4,327 |
MMBtu
|
$9.56 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $33,576 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $11,593 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.8121: Apply for tax-free status for energy purchases | $5,591 | - | - | - | - | - | $5,591 | |
02 | 2.8114: Change rate schedules or other changes in utility service | $2,577 | - | - | - | - | - | $2,577 | |
03 | 2.4231: Reduce the pressure of compressed air to the minimum required | $809 | - |
$809
12,818
kWh
|
- | - | - | - | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $704 | $287 |
$267
4,231
kWh
|
$23
-
kW-mo/yr
|
- | $260 | $154 | |
05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,357 | $1,200 |
$2,357
37,349
kWh
|
- | - | - | - | |
06 | 2.7243: Improve air circulation with destratification fans / other methods | $8,216 | $11,900 |
$(-1,252.0)
(-19,843)
kWh
|
$(-107.0)
-
kW-mo/yr
|
$9,575
-
MMBtu
|
- | - | |
07 | 2.6211: Conserve energy by efficient use of vending machines | $259 | $467 |
$259
4,099
kWh
|
- | - | - | - | |
08 | 2.7135: Install occupancy sensors | $416 | $778 |
$416
6,586
kWh
|
- | - | - | - | |
09 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $12,647 | $44,892 |
$9,427
149,396
kWh
|
$3,220
-
kW-mo/yr
|
- | - | - | |
TOTAL RECOMMENDED | $33,576 | $59,524 |
$12,283
194,636
kWh
|
$3,136
-
kW-mo/yr
|
$9,575
-
MMBtu
|
$260 | $8,322 | ||
TOTAL IMPLEMENTED | $11,593 | $1,667 |
$3,425
54,266
kWh
|
- | - | - | $8,168 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs