Assessment Year | 2009 |
---|---|
Principal Product | Sand and Gravel |
NAICS | 212321: Construction Sand and Gravel Mining |
SIC | 1442: Construction Sand and Gravel |
Sales Range | $1 M to 5M |
# of Employees | 15 |
Plant Area |
13,068,000
ft2
|
Annual Production | 265,000
ton
|
Production Hrs. Annual | 3,276
hrs
|
Location (State) | New York |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $2,187 | 16,440 |
kWh
|
$0.13 |
Electricity Demand | $535 | 56 |
kW-mo/yr
|
$9.55 |
Electricity Fees | $996 | - |
|
- |
Fuel Oil #2 | $392,848 | 97,099 |
MMBtu
|
$4.05 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $68,577 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $66,207 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Fuel Oil #2 Savings |
---|---|---|---|---|---|---|---|
01 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $3,788 | - | - | - |
$3,788
-
MMBtu
|
|
02 | 2.6211: Conserve energy by efficient use of vending machines | $181 | $197 |
$181
1,641
kWh
|
- | - | |
03 | 2.1321: Replace fossil fuel equipment with electrical equipment | $62,238 | $73,214 |
$(-125,931.0)
(-1,259,309)
kWh
|
$(-68,531.0)
-
kW-mo/yr
|
$256,700
-
MMBtu
|
|
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,370 | $4,766 |
$1,750
15,912
kWh
|
$620
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $68,577 | $78,177 |
$(-124,000.0)
(-1,241,756)
kWh
|
$(-67,911.0)
-
kW-mo/yr
|
$260,488
-
MMBtu
|
||
TOTAL IMPLEMENTED | $66,207 | $73,411 |
$(-125,750.0)
(-1,257,668)
kWh
|
$(-68,531.0)
-
kW-mo/yr
|
$260,488
-
MMBtu
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs