Assessment Year | 2009 |
---|---|
Principal Product | Precision Molds and Injection Molded Plastics |
NAICS | 326199: All Other Plastics Product Manufacturing |
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 115 |
Plant Area |
53,100
ft2
|
Annual Production | 75,000,000
pieces
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | New York |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $222,989 | 3,142,600 |
kWh
|
$0.071 |
Electricity Demand | $76,894 | 7,636 |
kW-mo/yr
|
$10.07 |
Electricity Fees | $(-5,150.0) | - |
|
- |
Natural Gas | $13,938 | 1,148 |
MMBtu
|
$12.14 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $26,455 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $13,606 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,251 | - |
$999
14,070
kWh
|
$252
-
kW-mo/yr
|
- | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,338 | $199 |
$1,066
15,008
kWh
|
$272
-
kW-mo/yr
|
- | |
03 | 2.7135: Install occupancy sensors | $789 | $575 |
$789
11,108
kWh
|
- | - | |
04 | 2.4131: Size electric motors for peak operating efficiency | $2,047 | $1,780 |
$1,201
16,915
kWh
|
$846
-
kW-mo/yr
|
- | |
05 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $3,801 | $3,568 |
$3,801
53,533
kWh
|
- | - | |
06 | 2.7314: Reduce ventilation air | $6,910 | $13,891 |
$282
3,978
kWh
|
$191
-
kW-mo/yr
|
$6,437
-
MMBtu
|
|
07 | 2.6211: Conserve energy by efficient use of vending machines | $91 | $288 |
$91
1,287
kWh
|
- | - | |
08 | 3.1191: Change procedures / equipment / operating conditions | $10,228 | $160,000 |
$6,719
94,644
kWh
|
$3,509
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $26,455 | $180,301 |
$14,948
210,543
kWh
|
$5,070
-
kW-mo/yr
|
$6,437
-
MMBtu
|
||
TOTAL IMPLEMENTED | $13,606 | $160,774 |
$9,573
134,830
kWh
|
$4,033
-
kW-mo/yr
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs