ITAC Assessment: SU0264
ITAC logo
ITAC Assessment: SU0264
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2008
Principal Product Cable Connectors
NAICS 332721: Precision Turned Product Manufacturing
SIC 3451: Screw Machine Products
Sales Range $50
M
to 100
M
# of Employees 352
Plant Area 106,000
ft2
Annual Production 28,500,000
pieces
Production Hrs. Annual 7,488
hrs
Location (State) New York

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $841,851 7,892,728
kWh
Electricity Demand $247,684 14,227
kW-mo/yr
Natural Gas $52,291 4,523
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $65,389 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $50,727

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings
01 2.4231: Reduce the pressure of compressed air to the minimum required $31,297 - $24,838
232,129
kWh
$6,459
-
kW-mo/yr
02 2.4111: Utilize energy-efficient belts and other improved mechanisms $9,914 - $7,355
68,739
kWh
$2,559
-
kW-mo/yr
03 2.4314: Use synthetic lubricant $4,440 - $3,413
31,899
kWh
$1,027
-
kW-mo/yr
04 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $3,015 $200 $2,388
22,314
kWh
$627
-
kW-mo/yr
05 2.6211: Conserve energy by efficient use of vending machines $308 $444 $308
2,878
kWh
-
06 2.7142: Utilize higher efficiency lamps and/or ballasts $16,415 $24,120 $13,020
121,680
kWh
$3,395
-
kW-mo/yr
TOTAL RECOMMENDED $65,389 $24,764 $51,322
479,639
kWh
$14,067
-
kW-mo/yr
TOTAL IMPLEMENTED $50,727 $24,320 $40,246
376,123
kWh
$10,481
-
kW-mo/yr
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs