Assessment Year | 2006 |
---|---|
Principal Product | Malleable and cast iron pipe fittings |
NAICS | 331511: Iron Foundries |
SIC | 3322: Malleable Iron Foundries |
Sales Range | $50 M to 100M |
# of Employees | 608 |
Plant Area |
430,000
ft2
|
Annual Production | 26,625
ton
|
Production Hrs. Annual | 5,600
hrs
|
Location (State) | Pennsylvania |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $1,335,151 | 35,425,201 |
kWh
|
$0.038 |
Electricity Demand | $861,944 | 88,495 |
kW-mo/yr
|
$9.74 |
Electricity Fees | $45,263 | - |
|
- |
Natural Gas | $2,746,125 | 385,968 |
MMBtu
|
$7.11 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $208,132 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $49,254 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.8114: Change rate schedules or other changes in utility service | $139,633 | - | - | - | - | - | $139,633 | |
02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $11,294 | - |
$6,589
176,624
kWh
|
$4,705
-
kW-mo/yr
|
- | - | - | |
03 | 2.4314: Use synthetic lubricant | $7,884 | - |
$4,202
111,412
kWh
|
$3,682
-
kW-mo/yr
|
- | - | - | |
04 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $6,673 | - |
$4,150
110,488
kWh
|
$2,523
-
kW-mo/yr
|
- | - | - | |
05 | 2.2511: Insulate bare equipment | $12,811 | $4,204 |
$(-212.0)
(-5,832)
kWh
|
$(-78.0)
-
kW-mo/yr
|
$13,101
-
MMBtu
|
- | - | |
06 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,265 | $524 |
$914
25,032
kWh
|
$351
-
kW-mo/yr
|
- | - | - | |
07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $27,530 | $32,632 |
$16,368
433,264
kWh
|
$11,162
-
kW-mo/yr
|
- | - | - | |
08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $849 | $1,005 |
$170
4,660
kWh
|
$58
-
kW-mo/yr
|
- | $454 | $167 | |
09 | 2.6211: Conserve energy by efficient use of vending machines | $126 | $632 |
$126
3,571
kWh
|
- | - | - | - | |
10 | 2.7135: Install occupancy sensors | $67 | $432 |
$67
1,623
kWh
|
- | - | - | - | |
TOTAL RECOMMENDED | $208,132 | $39,429 |
$32,374
860,842
kWh
|
$22,403
-
kW-mo/yr
|
$13,101
-
MMBtu
|
$454 | $139,800 | ||
TOTAL IMPLEMENTED | $49,254 | $38,997 |
$21,516
571,183
kWh
|
$14,016
-
kW-mo/yr
|
$13,101
-
MMBtu
|
$454 | $167 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs