Assessment Year | 2006 |
---|---|
Principal Product | Wine |
NAICS | 312130: Wineries |
SIC | 2084: Wines, Brandy, and Brandy Spirits |
Sales Range | $100 M to 500M |
# of Employees | 200 |
Plant Area |
361,000
ft2
|
Annual Production | 7,300,000
units
|
Production Hrs. Annual | 7,496
hrs
|
Location (State) | New York |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $428,757 | 7,573,500 |
kWh
|
$0.057 |
Electricity Demand | $141,043 | 18,145 |
kW-mo/yr
|
$7.77 |
Electricity Fees | $14,432 | - |
|
- |
Natural Gas | $521,148 | 540,747 |
MMBtu
|
$0.96 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $57,634 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $16,772 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.4231: Reduce the pressure of compressed air to the minimum required | $11,122 | - |
$8,028
140,844
kWh
|
$3,094
-
kW-mo/yr
|
- | |
02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $4,090 | - |
$3,305
57,989
kWh
|
$785
-
kW-mo/yr
|
- | |
03 | 2.4314: Use synthetic lubricant | $1,337 | - |
$1,073
18,815
kWh
|
$264
-
kW-mo/yr
|
- | |
04 | 2.1232: Keep boiler tubes clean | $8,242 | $1,800 | - | - |
$8,242
-
MMBtu
|
|
05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,758 | $823 |
$2,198
38,566
kWh
|
$560
-
kW-mo/yr
|
- | |
06 | 2.2414: Use waste heat from hot flue gases to preheat | $26,335 | $19,002 | - | - |
$26,335
-
MMBtu
|
|
07 | 2.6211: Conserve energy by efficient use of vending machines | $256 | $755 |
$217
3,811
kWh
|
$39
-
kW-mo/yr
|
- | |
08 | 2.7135: Install occupancy sensors | $89 | $266 |
$50
876
kWh
|
$39
-
kW-mo/yr
|
- | |
09 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $3,405 | $12,425 |
$2,457
43,109
kWh
|
$948
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $57,634 | $35,071 |
$17,328
304,010
kWh
|
$5,729
-
kW-mo/yr
|
$34,577
-
MMBtu
|
||
TOTAL IMPLEMENTED | $16,772 | $3,644 |
$6,843
120,057
kWh
|
$1,687
-
kW-mo/yr
|
$8,242
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs