Assessment Year 2004
Principal Product Flexible Packaging
NAICS 339999: All Other Miscellaneous Manufacturing
SIC 2671: Packaging Paper and Plastics Film, Coated and Laminated
Sales Range $50
M
to 100
M
# of Employees 129
Plant Area 100,000
ft2
Annual Production 31,500,000
thousand feet
Production Hrs. Annual 6,000
hrs
Location (State) New York

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $563,243 10,992,289
kWh
Electricity Demand $186,801 23,234
kW-mo/yr
Electricity Fees $31,462 -
Natural Gas $219,931 30,604
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $395,480 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $378,858

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings One-time Revenue or Avoided Cost Savings
01 2.7124: Make a practice of turning off lights when not needed $144 - $112
2,202
kWh
$32
-
kW-mo/yr
- -
02 2.4231: Reduce the pressure of compressed air to the minimum required $4,830 - $3,672
72,000
kWh
$1,158
-
kW-mo/yr
- -
03 4.431: Train operators for maximum operating efficiency $371,280 $13,500 - - - $371,280
04 2.2437: Recover waste heat from equipment $11,792 $1,184 - - $11,792
-
MMBtu
-
05 2.4314: Use synthetic lubricant $7,434 $2,000 $5,649
110,760
kWh
$1,785
-
kW-mo/yr
- -
TOTAL RECOMMENDED $395,480 $16,684 $9,433
184,962
kWh
$2,975
-
kW-mo/yr
$11,792
-
MMBtu
$371,280
TOTAL IMPLEMENTED $378,858 $15,500 $5,761
112,962
kWh
$1,817
-
kW-mo/yr
- $371,280
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs