ITAC Assessment: SU0151
ITAC logo
ITAC Assessment: SU0151
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2002
Principal Product corrugated shipping cartons
NAICS
n/a
SIC 2503:
Sales Range $10
M
to 50
M
# of Employees 117
Plant Area 167,722
ft2
Annual Production 685,000
thousand feet
Production Hrs. Annual 6,240
hrs
Location (State) New York

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $408,038 4,729,920
kWh
Electricity Demand $69,001 10,631
kW-mo/yr
Natural Gas $205,776 49,259
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $26,717 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $9,068

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Other Liquid (non-haz) Savings
01 3.4111: Use closed cycle process to minimize waste water production $7,975 $2,044 - - - $7,975
-
gal
02 2.4231: Reduce the pressure of compressed air to the minimum required $6,781 - $6,781
78,851
kWh
- - -
03 2.2437: Recover waste heat from equipment $3,604 $8,000 - - $3,604
-
MMBtu
-
04 2.7111: Reduce illumination to minimum necessary levels $3,447 $932 $3,447
47,874
kWh
- - -
05 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $2,287 $60 $2,287
31,766
kWh
- - -
06 2.4111: Utilize energy-efficient belts and other improved mechanisms $2,055 $1,635 $1,562
21,696
kWh
$493
-
kW-mo/yr
- -
07 2.7111: Reduce illumination to minimum necessary levels $568 - $568
7,884
kWh
- - -
TOTAL RECOMMENDED $26,717 $12,671 $14,645
188,071
kWh
$493
-
kW-mo/yr
$3,604
-
MMBtu
$7,975
-
gal
TOTAL IMPLEMENTED $9,068 $60 $9,068
110,617
kWh
- - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Other Liquid (non-haz) Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs