Assessment Year | 2002 |
---|---|
Principal Product | Electronic Controls |
NAICS |
n/a
|
SIC | 3625: Relays and Industrial Controls |
Sales Range | $10 M to 50M |
# of Employees | 300 |
Plant Area |
65,000
ft2
|
Annual Production | 1,600,000
pieces
|
Production Hrs. Annual | 2,080
hrs
|
Location (State) | New York |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $94,384 | 722,132 |
kWh
|
$0.13 |
Natural Gas | $22,515 | 2,542 |
MMBtu
|
$8.86 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $7,414 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $115 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|
01 | 3.6192: Use a less expensive method of waste removal | $4,500 | - | - | $4,500 | |
02 | 2.2437: Recover waste heat from equipment | $1,022 | $416 |
$1,022
14,602
kWh
|
- | |
03 | 2.2511: Insulate bare equipment | $781 | $125 |
$781
11,160
kWh
|
- | |
04 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $574 | $3,275 |
$574
8,207
kWh
|
- | |
05 | 2.7111: Reduce illumination to minimum necessary levels | $377 | - |
$377
5,382
kWh
|
- | |
06 | 2.7145: Install skylights | $115 | $697 |
$115
1,649
kWh
|
- | |
07 | 2.4221: Install compressor air intakes in coolest locations | $45 | $158 |
$45
483
kWh
|
- | |
TOTAL RECOMMENDED | $7,414 | $4,671 |
$2,914
41,483
kWh
|
$4,500 | ||
TOTAL IMPLEMENTED | $115 | $697 |
$115
1,649
kWh
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs