Assessment Year | 2001 |
---|---|
Principal Product | Plastic automotive parts |
NAICS |
n/a
|
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 210 |
Plant Area |
75,047
ft2
|
Annual Production | 22,041,827
pieces
|
Production Hrs. Annual | 5,760
hrs
|
Location (State) | New York |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $426,490 | 7,022,274 |
kWh
|
$0.061 |
Electricity Demand | $183,914 | 13,975 |
kW-mo/yr
|
$13.16 |
Electricity Fees | $36,000 | - |
|
- |
Natural Gas | $125,423 | 36,939 |
MMBtu
|
$3.40 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $176,310 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $25,915 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.6218: Turn off equipment when not in use | $3,222 | - |
$3,222
107,380
kWh
|
- | - | - | |
02 | 2.7111: Reduce illumination to minimum necessary levels | $1,645 | $225 |
$900
30,188
kWh
|
$745
-
kW-mo/yr
|
- | - | |
03 | 2.4231: Reduce the pressure of compressed air to the minimum required | $4,834 | - |
$4,834
161,130
kWh
|
- | - | - | |
04 | 2.3417: Use waste heat with a closed-cycle gas turbine-generator set to cogenerate electricity and heat | $64,282 | $500,000 |
$87,091
2,903,040
kWh
|
- |
$(-22,809.0)
-
MMBtu
|
- | |
05 | 2.3414: Burn waste to produce steam to drive a steam turbine generator set and use steam exhaust for heat | $81,279 | $750,000 | - | - |
$81,279
-
MMBtu
|
- | |
06 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $80 | - |
$80
2,685
kWh
|
- | - | - | |
07 | 2.2136: Install / repair insulation on steam lines | $6,188 | $8,325 | - | - |
$6,188
-
MMBtu
|
- | |
08 | 2.2135: Repair and eliminate steam leaks | $14,780 | $9,400 | - | - | - |
$14,780
-
Tgal
|
|
TOTAL RECOMMENDED | $176,310 | $1,267,950 |
$96,127
3,204,423
kWh
|
$745
-
kW-mo/yr
|
$64,658
-
MMBtu
|
$14,780
-
Tgal
|
||
TOTAL IMPLEMENTED | $25,915 | $17,950 |
$4,202
140,253
kWh
|
$745
-
kW-mo/yr
|
$6,188
-
MMBtu
|
$14,780
-
Tgal
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs