Assessment Year 1986
Principal Product CUSTOMIZED BERYLIUM COPPER
NAICS
n/a
SIC 3495: Wire Springs
Sales Range $10
M
to 50
M
# of Employees 263
Plant Area
n/a
Annual Production 200,000
pieces
Production Hrs. Annual 6,675
hrs
Location (State) Pennsylvania

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $356,018 5,025,205
kWh
Natural Gas $11,544 2,106
MMBtu
Fuel Oil #4 $40,365 7,484
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $111,523 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $32,844

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings Fuel Oil #4 Savings
01 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $4,729 $90 $4,729
66,823
kWh
- -
02 2.2437: Recover waste heat from equipment $698 $1,000 - - $698
-
MMBtu
03 2.1233: Analyze flue gas for proper air/fuel ratio $807 $537 - - $807
-
MMBtu
04 2.6121: Reduce hot water temperature to the minimum required $1,017 - $1,017
14,361
kWh
- -
05 2.1311: Replace electrically-operated equipment with fossil fuel equipment $1,719 $4,200 $2,541
35,756
kWh
$(-822.0)
-
MMBtu
-
06 2.7226: Use computer programs to optimize hvac performance $20,785 $36,000 $20,785
293,376
kWh
- -
07 2.7142: Utilize higher efficiency lamps and/or ballasts $4,345 $813 $4,345
61,254
kWh
- -
08 2.4111: Utilize energy-efficient belts and other improved mechanisms $463 $486 $463
6,448
kWh
- -
09 2.1311: Replace electrically-operated equipment with fossil fuel equipment $16,026 $30,000 $28,171
397,714
kWh
$(-12,145.0)
-
MMBtu
-
10 2.1311: Replace electrically-operated equipment with fossil fuel equipment $60,934 $175,000 $90,051
1,271,395
kWh
$(-29,117.0)
-
MMBtu
-
TOTAL RECOMMENDED $111,523 $248,126 $152,102
2,147,127
kWh
$(-42,084.0)
-
MMBtu
$1,505
-
MMBtu
TOTAL IMPLEMENTED $32,844 $38,926 $31,339
442,262
kWh
- $1,505
-
MMBtu
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings Fuel Oil #4 Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs