Assessment Year 1986
Principal Product METAL STAMPINGS
NAICS
n/a
SIC 3469: Metal Stampings, Not Elsewhere Classified
Sales Range $10
M
to 50
M
# of Employees 150
Plant Area
n/a
Annual Production 2,500,000
pieces
Production Hrs. Annual 2,825
hrs
Location (State) New York

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $136,522 711,899
kWh
Natural Gas $18,536 1,969
MMBtu
Fuel Oil #2 $15,147 2,611
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $34,693 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $14,293

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings Fuel Oil #2 Savings
01 2.4231: Reduce the pressure of compressed air to the minimum required $2,024 - $2,024
10,551
kWh
- -
02 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $9,556 - $9,556
49,824
kWh
- -
03 2.1233: Analyze flue gas for proper air/fuel ratio $1,589 $537 - $678
-
MMBtu
$911
-
MMBtu
04 2.7142: Utilize higher efficiency lamps and/or ballasts $5,060 $1,449 $5,060
26,377
kWh
- -
05 2.4133: Use most efficient type of electric motors $337 $1,167 $337
1,758
kWh
- -
06 2.4111: Utilize energy-efficient belts and other improved mechanisms $787 $1,775 $787
4,103
kWh
- -
07 2.7226: Use computer programs to optimize hvac performance $11,073 $10,000 $11,073
57,737
kWh
- -
08 2.7221: Lower temperature during the winter season and vice-versa $1,912 $3,500 - $1,054
-
MMBtu
$858
-
MMBtu
09 2.7494: Install storm windows and doors $2,355 $1,700 - $1,299
-
MMBtu
$1,056
-
MMBtu
TOTAL RECOMMENDED $34,693 $20,128 $28,837
150,350
kWh
$3,031
-
MMBtu
$2,825
-
MMBtu
TOTAL IMPLEMENTED $14,293 $3,479 $12,704
66,236
kWh
$678
-
MMBtu
$911
-
MMBtu
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings Fuel Oil #2 Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs