Assessment Year | 1986 |
---|---|
Principal Product | WOVEN LABELS |
NAICS |
n/a
|
SIC | 2241: Narrow Fabric and Other Smallware Mills: Cotton, Wool, Silk, and Manmade Fiber |
Sales Range | $10 M to 50M |
# of Employees | 132 |
Plant Area |
n/a
|
Annual Production | 8,000,000
pieces
|
Production Hrs. Annual | 7,200
hrs
|
Location (State) | New Jersey |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $146,245 | 1,674,678 |
kWh
|
$0.087 |
Natural Gas | $5,424 | 781 |
MMBtu
|
$6.94 |
Fuel Oil #2 | $12,689 | 1,952 |
MMBtu
|
$6.50 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $13,577 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $8,804 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Fuel Oil #2 Savings |
---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $8,108 | $6,443 |
$8,108
92,907
kWh
|
- | - | |
02 | 2.1233: Analyze flue gas for proper air/fuel ratio | $535 | $535 | - | - |
$535
-
MMBtu
|
|
03 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,761 | $1,469 |
$1,761
20,223
kWh
|
- | - | |
04 | 2.6121: Reduce hot water temperature to the minimum required | $161 | - | - |
$161
-
MMBtu
|
- | |
05 | 2.3191: Use demand controller or load shedder | $3,012 | $6,000 |
$3,012
-
kWh
|
- | - | |
TOTAL RECOMMENDED | $13,577 | $14,447 |
$12,881
113,130
kWh
|
$161
-
MMBtu
|
$535
-
MMBtu
|
||
TOTAL IMPLEMENTED | $8,804 | $6,978 |
$8,108
92,907
kWh
|
$161
-
MMBtu
|
$535
-
MMBtu
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs