| Assessment Year | 1985 |
|---|---|
| Principal Product | BATH ACCESSORIES |
| NAICS |
n/a
|
| SIC | 2392: House furnishing, Except Curtains and Draperies |
| Sales Range | $1 M to 5M |
| # of Employees | 220 |
| Plant Area |
n/a
|
| Annual Production | 2,500,000
pieces
|
| Production Hrs. Annual | 2,040
hrs
|
| Location (State) | New Jersey |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $176,681 | 939,625 |
kWh
|
$0.19 |
| Natural Gas | $289 | 28 |
MMBtu
|
$10.32 |
| Fuel Oil #2 | $28,130 | 4,410 |
MMBtu
|
$6.38 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $104,187 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $51,769 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Fuel Oil #2 Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $7,196 | $216 |
$7,196
38,394
kWh
|
- | - | |
| 02 | 2.2212: Use minimum safe oven ventilation | $3,945 | $250 |
$3,945
21,102
kWh
|
- | - | |
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $14,372 | $1,025 |
$14,372
76,495
kWh
|
- | - | |
| 04 | 2.1233: Analyze flue gas for proper air/fuel ratio | $1,350 | $537 | - |
$1,350
-
MMBtu
|
- | |
| 05 | 2.6124: Establish equipment maintenance schedule | $1,596 | - |
$1,716
9,086
kWh
|
- | $(-120.0) | |
| 06 | 3.4115: Recover and reuse cooling water | $700 | $1,000 |
$(-71.0)
(-293)
kWh
|
- | $771 | |
| 07 | 2.2414: Use waste heat from hot flue gases to preheat | $281 | $2,200 | - |
$281
-
MMBtu
|
- | |
| 08 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $2,777 | $1,900 |
$2,777
-
kWh
|
- | - | |
| 09 | 2.7224: Reduce space conditioning during non-working hours | $25,374 | - |
$14,654
77,667
kWh
|
$10,720
-
MMBtu
|
- | |
| 10 | 2.7494: Install storm windows and doors | $14,477 | $8,500 |
$10,886
58,030
kWh
|
$3,591
-
MMBtu
|
- | |
| 11 | 2.7492: Use proper thickness of insulation on building envelope | $32,119 | $10,000 |
$26,234
139,508
kWh
|
$5,885
-
MMBtu
|
- | |
| TOTAL RECOMMENDED | $104,187 | $25,628 |
$81,709
419,989
kWh
|
$21,827
-
MMBtu
|
$651 | ||
| TOTAL IMPLEMENTED | $51,769 | $4,678 |
$38,928
192,263
kWh
|
$12,070
-
MMBtu
|
$771 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Fuel Oil #2 Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs