| Assessment Year | 1985 |
|---|---|
| Principal Product | EXPENDABLE PROBES |
| NAICS |
n/a
|
| SIC | 3823: Industrial Instruments for Measurement, Display, and Control of Process Variables; and Related Products |
| Sales Range | $10 M to 50M |
| # of Employees | 215 |
| Plant Area |
n/a
|
| Annual Production | 500,000
pieces
|
| Production Hrs. Annual | 3,904
hrs
|
| Location (State) | Pennsylvania |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $200,878 | 2,701,055 |
kWh
|
$0.074 |
| Natural Gas | $51,034 | 7,277 |
MMBtu
|
$7.01 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $33,829 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $19,161 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.6212: Turn off equipment during breaks, reduce operating time | $196 | - |
$196
2,638
kWh
|
- | |
| 02 | 2.6212: Turn off equipment during breaks, reduce operating time | $65 | $95 |
$65
879
kWh
|
- | |
| 03 | 2.2437: Recover waste heat from equipment | $1,844 | $1,600 | - |
$1,844
-
MMBtu
|
|
| 04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $893 | $112 |
$893
12,016
kWh
|
- | |
| 05 | 2.7242: Change zone reheat coils to variable air volume boxes | $2,549 | $3,000 |
$1,765
23,740
kWh
|
$784
-
MMBtu
|
|
| 06 | 2.1123: Install automatic stack damper | $200 | $2,550 | - |
$200
-
MMBtu
|
|
| 07 | 2.6121: Reduce hot water temperature to the minimum required | $1,678 | - |
$1,678
22,567
kWh
|
- | |
| 08 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $1,190 | $1,428 |
$1,961
26,377
kWh
|
$(-771.0)
-
MMBtu
|
|
| 09 | 2.2511: Insulate bare equipment | $44 | $26 |
$44
586
kWh
|
- | |
| 10 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $7,186 | $1,900 |
$7,186
-
kWh
|
- | |
| 11 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $7,038 | $2,186 |
$7,038
94,666
kWh
|
- | |
| 12 | 2.7224: Reduce space conditioning during non-working hours | $8,820 | - | - |
$8,820
-
MMBtu
|
|
| 13 | 2.7447: Install vinyl strip / high speed / air curtain doors | $2,126 | $76 | - |
$2,126
-
MMBtu
|
|
| TOTAL RECOMMENDED | $33,829 | $12,973 |
$20,826
183,469
kWh
|
$13,003
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $19,161 | $4,300 |
$17,035
132,473
kWh
|
$2,126
-
MMBtu
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs