| Assessment Year | 2026 |
|---|---|
| Principal Product | Ground & Whole Bean Coffee |
| NAICS | 311920: Coffee and Tea Manufacturing |
| SIC | 2095: Roasted Coffee |
| Sales Range | $10 M to 50M |
| # of Employees | 50 |
| Plant Area |
75,000
ft2
|
| Annual Production | 71,000
lb
|
| Production Hrs. Annual | 3,250
hrs
|
| Location (State) | California |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $149,788 | 427,895 |
kWh
|
$0.35 |
| Electricity Demand | $45,615 | 1,858 |
kW-mo/yr
|
$24.55 |
| Natural Gas | $78,549 | 3,752 |
MMBtu
|
$20.94 |
| TOTAL YEARLY COSTS | $273,952 | |||
| RECOMMENDED SAVINGS* | $110,844 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Primary Product Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $986 | - |
$937
2,678
kWh
|
$49
-
kW-mo/yr
|
- | - | |
| 02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $868 | - |
$735
2,100
kWh
|
$133
-
kW-mo/yr
|
- | - | |
| 03 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $989 | $7,310 | - |
$989
-
kW-mo/yr
|
- | - | |
| 04 | 2.9114: Use solar heat to make electricty | $105,896 | $509,829 |
$105,896
302,560
kWh
|
- | - | - | |
| 05 | 2.8112: Combine utility meters | $2,104 | - | - | - | $2,104 | - | |
| 06 | 2.3142: User battery storage for power quality issues | $1 | - | - | - | - | $1 | |
| TOTAL RECOMMENDED | $110,844 | $517,139 |
$107,568
307,338
kWh
|
$1,171
-
kW-mo/yr
|
$2,104 | $1 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Primary Product Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs