| Assessment Year | 2026 |
|---|---|
| Principal Product | Wine |
| NAICS | 312130: Wineries |
| SIC | 2084: Wines, Brandy, and Brandy Spirits |
| Sales Range | $100 M to 500M |
| # of Employees | 400 |
| Plant Area |
10,600,000
ft2
|
| Annual Production | 1,000,000
units
|
| Production Hrs. Annual | 8,760
hrs
|
| Location (State) | California |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $1,666,920 | 19,011,656 |
kWh
|
$0.088 | |
| Electricity Demand | $1,101,212 | 46,764 |
kW-mo/yr
|
$23.55 | |
| LPG | $709,934 | 38,686 |
MMBtu
|
$18.35 | |
| Waste Disposal Costs | |||||
| Other Liquid (non-haz) | $417,275 | 297,728 |
gal
|
$1.40 | |
| TOTAL YEARLY COSTS | $3,895,341 | ||||
| RECOMMENDED SAVINGS* | $618,294 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | - | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | LPG Savings | Other Liquid (non-haz) Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $6,874 | $29,414 |
$2,828
32,156
kWh
|
$4,046
-
kW-mo/yr
|
- | - | |
| 02 | 2.2621: Modify refrigeration system to operate at a lower pressure | $61,426 | $144,392 |
$48,874
555,384
kWh
|
$12,552
-
kW-mo/yr
|
- | - | |
| 03 | 2.9114: Use solar heat to make electricty | $125,925 | $1,344,513 |
$92,280
1,048,630
kWh
|
$33,645
-
kW-mo/yr
|
- | - | |
| 04 | 4.212: Adopt in-house material generation | $357,338 | $572,004 |
$(-20,891.0)
(-237,396)
kWh
|
$(-39,046.0)
-
kW-mo/yr
|
- |
$417,275
-
gal
|
|
| 05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,865 | $1,023 |
$946
10,753
kWh
|
$919
-
kW-mo/yr
|
- | - | |
| 06 | 2.2511: Insulate bare equipment | $37,880 | $17,625 | - | - |
$37,880
-
MMBtu
|
- | |
| 07 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $26,986 | - |
$22,457
255,201
kWh
|
$4,529
-
kW-mo/yr
|
- | - | |
| TOTAL RECOMMENDED | $618,294 | $2,108,971 |
$146,494
1,664,728
kWh
|
$16,645
-
kW-mo/yr
|
$37,880
-
MMBtu
|
$417,275
-
gal
|
||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | LPG Savings | Other Liquid (non-haz) Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs