| Assessment Year | 2025 |
|---|---|
| Principal Product | Bonded Carpet Cushion |
| NAICS | 326150: Urethane and Other Foam Product (except Polystyrene) Manufacturing |
| SIC | 3086: Plastics Foam Products |
| Sales Range | $50 M to 100M |
| # of Employees | 83 |
| Plant Area |
384,634
ft2
|
| Annual Production | 800,000
units
|
| Production Hrs. Annual | 5,100
hrs
|
| Location (State) | California |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $564,251 | 4,209,058 |
kWh
|
$0.13 | |
| Electricity Demand | $836,231 | 13,590 |
kW-mo/yr
|
$61.53 | |
| Natural Gas | $127,197 | 10,121 |
MMBtu
|
$12.57 | |
| Other Energy | $33,696 | 1,788 |
MMBtu
|
$18.85 | |
| Waste Disposal Costs | |||||
| Water Usage | $54,802 | 1,536 |
Tgal
|
$35.68 | |
| TOTAL YEARLY COSTS | $1,616,177 | ||||
| RECOMMENDED SAVINGS* | $309,632 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | - | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Other Liquid (haz) Savings | Water Consumption Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $26,657 | $43,400 |
$12,813
95,625
kWh
|
$13,844
-
kW-mo/yr
|
- | - | - | |
| 02 | 2.2511: Insulate bare equipment | $462 | $798 | - | - |
$462
-
MMBtu
|
- | - | |
| 03 | 2.1243: Use heat from boiler blowdown to preheat boiler feed water | $258 | $1,739 | - | - |
$258
-
MMBtu
|
- | - | |
| 04 | 2.1241: Reduce excessive boiler blowdown | $1,078 | $2,456 | - | - |
$113
-
MMBtu
|
$953
-
gal
|
$12
-
Tgal
|
|
| 05 | 2.7135: Install occupancy sensors | $19,412 | $41,750 |
$11,167
83,335
kWh
|
$8,245
-
kW-mo/yr
|
- | - | - | |
| 06 | 2.4239: Eliminate or reduce compressed air usage | $2,422 | $1,167 |
$2,360
17,612
kWh
|
$62
-
kW-mo/yr
|
- | - | - | |
| 07 | 2.4239: Eliminate or reduce compressed air usage | $1,004 | - |
$652
4,868
kWh
|
$352
-
kW-mo/yr
|
- | - | - | |
| 08 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,895 | - |
$2,529
18,870
kWh
|
$1,366
-
kW-mo/yr
|
- | - | - | |
| 09 | 2.9114: Use solar heat to make electricty | $254,444 | $1,522,550 |
$199,482
1,488,669
kWh
|
$54,962
-
kW-mo/yr
|
- | - | - | |
| TOTAL RECOMMENDED | $309,632 | $1,613,860 |
$229,003
1,708,979
kWh
|
$78,831
-
kW-mo/yr
|
$833
-
MMBtu
|
$953
-
gal
|
$12
-
Tgal
|
||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Other Liquid (haz) Savings | Water Consumption Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs