Assessment Year | 2025 |
---|---|
Principal Product | Ceramic tiles |
NAICS | 327120: Clay Building Material and Refractories Manufacturing |
SIC | 3253: Ceramic Wall and Floor Tile |
Sales Range | $10 M to 50M |
# of Employees | 140 |
Plant Area |
80,000
ft2
|
Annual Production | 1,000,000
units
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $167,167 | 842,579 |
kWh
|
$0.20 |
Electricity Demand | $128,400 | 3,329 |
kW-mo/yr
|
$38.57 |
Electricity Fees | $(-48,523.0) | - |
|
- |
Natural Gas | $657,041 | 48,132 |
MMBtu
|
$13.65 |
TOTAL YEARLY COSTS | $904,085 | |||
RECOMMENDED SAVINGS* | $84,389 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,057 | - |
$832
4,182
kWh
|
$225
-
kW-mo/yr
|
- | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $8,359 | - |
$7,449
37,431
kWh
|
$910
-
kW-mo/yr
|
- | |
03 | 2.6218: Turn off equipment when not in use | $9,425 | - |
$9,425
47,353
kWh
|
- | - | |
04 | 2.2511: Insulate bare equipment | $8,955 | $2,910 | - | - |
$8,955
-
MMBtu
|
|
05 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $1,968 | $1,703 |
$952
4,786
kWh
|
$1,016
-
kW-mo/yr
|
- | |
06 | 2.7135: Install occupancy sensors | $37,951 | $77,070 |
$37,951
190,706
kWh
|
- | - | |
07 | 2.2443: Re-use or recycle hot or cold process exhaust air | $15,818 | $11,594 |
$(-5,141.0)
(-25,834)
kWh
|
$(-1,917.0)
-
kW-mo/yr
|
$22,876
-
MMBtu
|
|
08 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $856 | $3,293 |
$856
3,243
kWh
|
- | - | |
TOTAL RECOMMENDED | $84,389 | $96,570 |
$52,324
261,867
kWh
|
$234
-
kW-mo/yr
|
$31,831
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs