Assessment Year 2024
Principal Product Tortilla, Tortilla Chips
NAICS 311830: Tortilla Manufacturing
SIC 2099: Food Preparations, Not Elsewhere Classified
Sales Range $1
M
to 5
M
# of Employees 23
Plant Area 35,000
ft2
Annual Production 2,000,000
units
Production Hrs. Annual 2,040
hrs
Location (State) California

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $64,185 285,712
kWh
Electricity Demand $31,377 1,782
kW-mo/yr
Natural Gas $74,719 4,094
MMBtu
TOTAL YEARLY COSTS $170,281
RECOMMENDED SAVINGS* $77,090 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Natural Gas Savings
01 2.9114: Use solar heat to make electricty $47,814 $107,262 $41,268
183,990
kWh
$6,546
-
kW-mo/yr
- -
02 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $2,372 $104 $2,372
10,542
kWh
- - -
03 2.6127: Maintain air filters by cleaning or replacement $28 $235 $7
33
kWh
$21
-
kW-mo/yr
- -
04 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $3,556 $4,600 $865
3,851
kWh
$2,691
-
kW-mo/yr
- -
05 2.4239: Eliminate or reduce compressed air usage $733 - $489
2,174
kWh
$244
-
kW-mo/yr
- -
06 2.6212: Turn off equipment during breaks, reduce operating time $20,579 - - - - $20,579
-
MMBtu
07 2.4111: Utilize energy-efficient belts and other improved mechanisms $155 $22 $155
689
kWh
- - -
08 2.2511: Insulate bare equipment $1,399 $1,473 - - - $1,399
-
MMBtu
09 2.8112: Combine utility meters $454 - - - $454 -
TOTAL RECOMMENDED $77,090 $113,696 $45,156
201,279
kWh
$9,502
-
kW-mo/yr
$454 $21,978
-
MMBtu
TOTAL IMPLEMENTED - - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs