Assessment Year | 2023 |
---|---|
Principal Product | battery electrolytes |
NAICS | 325998: All Other Miscellaneous Chemical Product and Preparation Manufacturing |
SIC | 2899: Chemicals and Chemical Preparations, Not Elsewhere Classified |
Sales Range | $500 k to 1M |
# of Employees | 8 |
Plant Area |
32,000
ft2
|
Annual Production | 50
ton
|
Production Hrs. Annual | 2,346
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $88,999 | 430,259 |
kWh
|
$0.21 |
Electricity Demand | $39,349 | 990 |
kW-mo/yr
|
$39.75 |
Natural Gas | $10,557 | 478 |
MMBtu
|
$22.09 |
TOTAL YEARLY COSTS | $138,905 | |||
RECOMMENDED SAVINGS* | $14,109 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $630 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.9114: Use solar heat to make electricty | $13,195 | $77,365 |
$13,195
80,952
kWh
|
- | |
02 | 2.6218: Turn off equipment when not in use | $365 | - |
$365
2,237
kWh
|
- | |
03 | 2.4231: Reduce the pressure of compressed air to the minimum required | $80 | - |
$80
488
kWh
|
- | |
04 | 2.4133: Use most efficient type of electric motors | $126 | $436 |
$56
342
kWh
|
$70
-
kW-mo/yr
|
|
05 | 2.2511: Insulate bare equipment | $265 | $344 |
$265
1,623
kWh
|
- | |
06 | 2.7135: Install occupancy sensors | $78 | $177 |
$78
245
kWh
|
- | |
TOTAL RECOMMENDED | $14,109 | $78,322 |
$14,039
85,887
kWh
|
$70
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | $630 | $344 |
$630
3,860
kWh
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs