| Assessment Year | 2026 |
|---|---|
| Principal Product | Red and White Wines |
| NAICS | 312130: Wineries |
| SIC | 2084: Wines, Brandy, and Brandy Spirits |
| Sales Range | $5 M to 10M |
| # of Employees | 30 |
| Plant Area |
43,700
ft2
|
| Annual Production | 540,000
units
|
| Production Hrs. Annual | 2,568
hrs
|
| Location (State) | California |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $124,510 | 531,899 |
kWh
|
$0.23 |
| Electricity Demand | $54,752 | 1,170 |
kW-mo/yr
|
$46.80 |
| LPG | $51,901 | 1,276 |
MMBtu
|
$40.67 |
| TOTAL YEARLY COSTS | $231,163 | |||
| RECOMMENDED SAVINGS* | $156,486 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | LPG Savings | Personnel Changes Savings | Primary Raw Material Savings | Ancillary Material Cost Savings |
|---|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.6218: Turn off equipment when not in use | $8,908 | - |
$6,993
29,873
kWh
|
$1,915
-
kW-mo/yr
|
- | - | - | - | |
| 02 | 2.6218: Turn off equipment when not in use | $457 | - |
$457
1,951
kWh
|
- | - | - | - | - | |
| 03 | 2.4231: Reduce the pressure of compressed air to the minimum required | $4,283 | $420 |
$187
799
kWh
|
$4,096
-
kW-mo/yr
|
- | - | - | - | |
| 04 | 2.2511: Insulate bare equipment | $2,383 | $358 | - | - |
$2,383
-
MMBtu
|
- | - | - | |
| 05 | 2.7224: Reduce space conditioning during non-working hours | $23,134 | $4,215 |
$1,833
7,826
kWh
|
- |
$21,301
-
MMBtu
|
- | - | - | |
| 06 | 2.7495: Install replacement doors | $19,550 | $30,389 |
$19,550
83,529
kWh
|
- | - | - | - | - | |
| 07 | 2.2622: Replace existing chiller with high efficiency model | $76,884 | $128,772 |
$7,602
32,472
kWh
|
$2,082
-
kW-mo/yr
|
- | - | - | $67,200 | |
| 08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $15,321 | $27,270 |
$6,766
28,900
kWh
|
$6,320
-
kW-mo/yr
|
- | $2,081 | $154 | - | |
| 09 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $5,566 | $24,058 |
$5,566
23,776
kWh
|
- | - | - | - | - | |
| TOTAL RECOMMENDED | $156,486 | $215,482 |
$48,954
209,126
kWh
|
$14,413
-
kW-mo/yr
|
$23,684
-
MMBtu
|
$2,081 | $154 | $67,200 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | LPG Savings | Personnel Changes Savings | Primary Raw Material Savings | Ancillary Material Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs