| Assessment Year | 2026 |
|---|---|
| Principal Product | Glass |
| NAICS | 327211: Flat Glass Manufacturing |
| SIC | 3211: Flat Glass |
| Sales Range | $100 M to 500M |
| # of Employees | 160 |
| Plant Area |
260,000
ft2
|
| Annual Production | 90,000,000
units
|
| Production Hrs. Annual | 8,760
hrs
|
| Location (State) | California |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $3,245,875 | 28,888,504 |
kWh
|
$0.11 | |
| Electricity Demand | $479,624 | 55,358 |
kW-mo/yr
|
$8.66 | |
| Natural Gas | $2,455 | 105 |
MMBtu
|
$23.38 | |
| Waste Disposal Costs | |||||
| Water Usage | $134,503 | 68,052 |
Tgal
|
$1.98 | |
| Water Disposal | $137,597 | 13,523 |
Tgal
|
$10.18 | |
| TOTAL YEARLY COSTS | $4,000,054 | ||||
| RECOMMENDED SAVINGS* | $153,847 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | - | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Water Usage Savings | Water Disposal Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $21,138 | $7,872 |
$21,138
188,065
kWh
|
- | - | - | - | - | - | |
| 02 | 2.7224: Reduce space conditioning during non-working hours | $5,780 | $4,983 |
$5,780
51,426
kWh
|
- | - | - | - | - | - | |
| 03 | 2.3132: Recharge batteries on during off-peak demand periods | $4,938 | $5,263 | - |
$2,095
-
kW-mo/yr
|
$2,843 | - | - | - | - | |
| 04 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $313 | $462 |
$270
2,400
kWh
|
$44
-
kW-mo/yr
|
- | - | - | - | - | |
| 05 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $7,632 | $21,317 |
$7,632
67,908
kWh
|
- | - | - | - | - | - | |
| 06 | 2.7134: Use photocell controls | $2,716 | $12,669 |
$1,929
17,164
kWh
|
- | - | - | - | $81 | $706 | |
| 07 | 3.4114: Replace city water with recycled water via cooling tower | $111,329 | $388,045 |
$(-4,853.0)
(-43,174)
kWh
|
- | - |
$20,171
-
Tgal
|
$103,865
-
Tgal
|
$(-7,854.0) | - | |
| TOTAL RECOMMENDED | $153,847 | $440,611 |
$31,896
283,789
kWh
|
$2,139
-
kW-mo/yr
|
$2,843 |
$20,171
-
Tgal
|
$103,865
-
Tgal
|
$(-7,773.0) | $706 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Water Usage Savings | Water Disposal Savings | Personnel Changes Savings | Ancillary Material Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs