Assessment Year 2026
Principal Product customized LED lighting systems
NAICS 335110: Electric Lamp Bulb and Part Manufacturing
SIC 3641: Electric Lamp Bulbs and Tubes
Sales Range $100
M
to 500
M
# of Employees 240
Plant Area 142,000
ft2
Annual Production 1,400
thousand feet
Production Hrs. Annual 3,125
hrs
Location (State) California

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $244,996 614,325
kWh
Electricity Demand $36,167 2,508
kW-mo/yr
TOTAL YEARLY COSTS $281,163
RECOMMENDED SAVINGS* $58,421 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Personnel Changes Savings Primary Raw Material Savings
01 2.7224: Reduce space conditioning during non-working hours $31,834 $2,250 $31,834
79,825
kWh
- - - -
02 2.4231: Reduce the pressure of compressed air to the minimum required $496 $160 $181
454
kWh
$315
-
kW-mo/yr
- - -
03 2.3132: Recharge batteries on during off-peak demand periods $2,835 $4,194 - - $2,835 - -
04 2.7224: Reduce space conditioning during non-working hours $13,854 $29,876 $13,854
34,740
kWh
- - - -
05 2.7135: Install occupancy sensors $860 $2,740 $750
1,880
kWh
- - $4 $106
06 2.7291: Reschedule and rearrange multiple-source heating systems $8,542 $50,720 $8,542
21,420
kWh
- - - -
TOTAL RECOMMENDED $58,421 $89,940 $55,161
138,319
kWh
$315
-
kW-mo/yr
$2,835 $4 $106
TOTAL IMPLEMENTED - - - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Personnel Changes Savings Primary Raw Material Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs