| Assessment Year | 2026 |
|---|---|
| Principal Product | Die Cast Parts |
| NAICS | 331523: Nonferrous Metal Die-Casting Foundries |
| SIC | 3363: Aluminum Die-Castings |
| Sales Range | $10 M to 50M |
| # of Employees | 50 |
| Plant Area |
60,000
ft2
|
| Annual Production | 250,000
units
|
| Production Hrs. Annual | 8,760
hrs
|
| Location (State) | California |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $288,641 | 1,490,003 |
kWh
|
$0.19 | |
| Electricity Demand | $337,284 | 6,915 |
kW-mo/yr
|
$48.78 | |
| Natural Gas | $33,197 | 1,234 |
MMBtu
|
$26.90 | |
| Waste Disposal Costs | |||||
| Water Usage | $26,794 | 965 |
Tgal
|
$27.77 | |
| TOTAL YEARLY COSTS | $685,916 | ||||
| RECOMMENDED SAVINGS* | $406,173 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | - | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Personnel Changes Savings | Primary Raw Material Savings |
|---|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $13,514 | - |
$10,714
55,314
kWh
|
- | - | - | $2,800 | - | |
| 02 | 2.6218: Turn off equipment when not in use | $818 | - |
$818
4,223
kWh
|
- | - | - | - | - | |
| 03 | 2.3191: Use demand controller or load shedder | $69,072 | - | - |
$69,072
-
kW-mo/yr
|
- | - | - | - | |
| 04 | 2.6218: Turn off equipment when not in use | $1,029 | - |
$1,029
5,314
kWh
|
- | - | - | - | - | |
| 05 | 2.7224: Reduce space conditioning during non-working hours | $11,683 | $2,000 |
$3,560
18,378
kWh
|
- | - |
$8,123
-
MMBtu
|
- | - | |
| 06 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,268 | $350 |
$747
3,857
kWh
|
$521
-
kW-mo/yr
|
- | - | - | - | |
| 07 | 2.1131: Repair faulty insulation in furnaces, boilers, etc | $11,403 | $3,643 |
$11,403
58,871
kWh
|
- | - | - | - | - | |
| 08 | 2.2531: Re-size charging openings or add movable cover or door | $8,178 | $5,000 |
$8,178
42,219
kWh
|
- | - | - | - | - | |
| 09 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $9,207 | $8,069 |
$3,979
20,543
kWh
|
$5,228
-
kW-mo/yr
|
- | - | - | - | |
| 10 | 2.8114: Change rate schedules or other changes in utility service | $87,216 | $146,113 | - | - | $87,216 | - | - | - | |
| 11 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $13,685 | $23,706 |
$7,439
38,402
kWh
|
$5,785
-
kW-mo/yr
|
- | - | $427 | $34 | |
| 12 | 2.3141: Use battery storage for demand control | $39,673 | $145,800 | - |
$42,293
-
kW-mo/yr
|
$(-2,620.0) | - | - | - | |
| 13 | 2.9114: Use solar heat to make electricty | $139,427 | $781,676 |
$139,427
719,810
kWh
|
- | - | - | - | - | |
| TOTAL RECOMMENDED | $406,173 | $1,116,357 |
$187,294
966,931
kWh
|
$122,899
-
kW-mo/yr
|
$84,596 |
$8,123
-
MMBtu
|
$3,227 | $34 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Personnel Changes Savings | Primary Raw Material Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs