Assessment Year | 2024 |
---|---|
Principal Product | Synthetic Peptides |
NAICS | 325412: Pharmaceutical Preparation Manufacturing |
SIC | 2834: Pharmaceutical Preparations |
Sales Range | $10 M to 50M |
# of Employees | 75 |
Plant Area |
30,000
ft2
|
Annual Production | 12,000,000
lb
|
Production Hrs. Annual | 2,340
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $183,131 | 1,017,657 |
kWh
|
$0.18 |
Electricity Demand | $92,329 | 3,378 |
kW-mo/yr
|
$27.33 |
Electricity Fees | $275,765 | - |
|
- |
Natural Gas | $52,456 | 2,664 |
MMBtu
|
$19.69 |
TOTAL YEARLY COSTS | $603,681 | |||
RECOMMENDED SAVINGS* | $75,087 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.6218: Turn off equipment when not in use | $72,544 | - |
$62,719
347,861
kWh
|
- |
$9,825
-
MMBtu
|
- | - | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,482 | $770 |
$1,091
6,053
kWh
|
$228
-
kW-mo/yr
|
- | $42 | $121 | |
03 | 4.132: Purchase new equipment to reduce material use / cost | $1,061 | $6,460 |
$864
4,792
kWh
|
$197
-
kW-mo/yr
|
- | - | - | |
TOTAL RECOMMENDED | $75,087 | $7,230 |
$64,674
358,706
kWh
|
$425
-
kW-mo/yr
|
$9,825
-
MMBtu
|
$42 | $121 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs