Assessment Year | 2017 |
---|---|
Principal Product | Printing |
NAICS | 322212: Folding Paperboard Box Manufacturing |
SIC | 2657: Folding Paperboard Boxes, Including Sanitary |
Sales Range | $10 M to 50M |
# of Employees | 60 |
Plant Area |
96,515
ft2
|
Annual Production | 108,000,000
units
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | Washington |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $178,884 | 2,104,520 |
kWh
|
$0.085 |
Electricity Demand | $1 | 6,239 |
kW-mo/yr
|
$0.000 |
Electricity Fees | $12,075 | - |
|
- |
Natural Gas | $86,421 | 13,186 |
MMBtu
|
$6.55 |
TOTAL YEARLY COSTS | $277,381 | |||
RECOMMENDED SAVINGS* | $36,866 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $12,652 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.2437: Recover waste heat from equipment | $3,431 | $448 | - | - |
$3,431
-
MMBtu
|
|
02 | 2.7232: Replace existing hvac unit with high efficiency model | $9,221 | $180,000 |
$4,928
57,978
kWh
|
- |
$4,293
-
MMBtu
|
|
03 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $3,049 | - |
$3,049
35,873
kWh
|
- | - | |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $21,165 | - |
$21,164
248,991
kWh
|
$1
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $36,866 | $180,448 |
$29,141
342,842
kWh
|
$1
-
kW-mo/yr
|
$7,724
-
MMBtu
|
||
TOTAL IMPLEMENTED | $12,652 | $180,448 |
$4,928
57,978
kWh
|
- |
$7,724
-
MMBtu
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs