Assessment Year | 2024 |
---|---|
Principal Product | Ceramic tile |
NAICS | 327110: Pottery, Ceramics, and Plumbing Fixture Manufacturing |
SIC | 3269: Pottery Products, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 44 |
Plant Area |
48,000
ft2
|
Annual Production | 41,000
units
|
Production Hrs. Annual | 2,875
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $143,277 | 643,641 |
kWh
|
$0.22 |
Electricity Demand | $40,494 | 1,972 |
kW-mo/yr
|
$20.53 |
Natural Gas | $249,809 | 12,852 |
MMBtu
|
$19.44 |
TOTAL YEARLY COSTS | $433,580 | |||
RECOMMENDED SAVINGS* | $71,229 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings |
---|---|---|---|---|---|---|---|
01 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $9,331 | $1,971 |
$9,331
41,917
kWh
|
- | - | |
02 | 2.4239: Eliminate or reduce compressed air usage | $292 | $292 |
$211
949
kWh
|
$81
-
kW-mo/yr
|
- | |
03 | 2.3132: Recharge batteries on during off-peak demand periods | $551 | $550 | - | - | $551 | |
04 | 2.9114: Use solar heat to make electricty | $61,055 | $261,561 |
$61,055
274,282
kWh
|
- | - | |
TOTAL RECOMMENDED | $71,229 | $264,374 |
$70,597
317,148
kWh
|
$81
-
kW-mo/yr
|
$551 | ||
TOTAL IMPLEMENTED | - | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs