Assessment Year | 2024 |
---|---|
Principal Product | Baked Products & Wholesale Foods |
NAICS | 311812: Commercial Bakeries |
SIC | 2051: Bread and Other Bakery Products, Except Cookies and Crackers |
Sales Range | $10 M to 50M |
# of Employees | 130 |
Plant Area |
20,000
ft2
|
Annual Production | 4,927,500
units
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $106,077 | 584,761 |
kWh
|
$0.18 |
Electricity Demand | $46,587 | 1,377 |
kW-mo/yr
|
$33.83 |
Electricity Fees | $5,271 | - |
|
- |
Natural Gas | $97,607 | 5,200 |
MMBtu
|
$18.77 |
Fuel Oil #2 | $71,193 | 1,785 |
MMBtu
|
$39.88 |
Other Energy | $108,089 | 2,620 |
MMBtu
|
$41.26 |
TOTAL YEARLY COSTS | $434,824 | |||
RECOMMENDED SAVINGS* | $109,695 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Other Energy Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.7447: Install vinyl strip / high speed / air curtain doors | $2,332 | $226 |
$2,332
12,853
kWh
|
- | - | - | - | |
02 | 2.7442: Keep doors and windows shut when not on use | $175 | $59 |
$175
967
kWh
|
- | - | - | - | |
03 | 2.1321: Replace fossil fuel equipment with electrical equipment | $73,026 | $18,461 |
$(-26,672.0)
(-147,034)
kWh
|
- |
$91,431
-
MMBtu
|
- | $8,267 | |
04 | 2.2522: Isolate hot or cold equipment | $3,665 | $4,130 |
$2,515
13,862
kWh
|
- | - | $1,150 | - | |
05 | 2.2515: Use optimum thickness insulation | $106 | $151 |
$106
583
kWh
|
- | - | - | - | |
06 | 2.2425: Use flue gases to heat process or service water | $21,923 | $54,880 | - |
$21,923
-
MMBtu
|
- | - | - | |
07 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $8,468 | $41,738 |
$8,468
46,681
kWh
|
- | - | - | - | |
TOTAL RECOMMENDED | $109,695 | $119,645 |
$(-13,076.0)
(-72,088)
kWh
|
$21,923
-
MMBtu
|
$91,431
-
MMBtu
|
$1,150 | $8,267 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Other Energy Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs