Assessment Year | 2022 |
---|---|
Principal Product | Dried figs, raisins, paste and concentrate |
NAICS | 311423: Dried and Dehydrated Food Manufacturing |
SIC | 2034: Dried and Dehydrated Fruits, Vegetables, and Soup Mixes |
Sales Range | $10 M to 50M |
# of Employees | 65 |
Plant Area |
645,000
ft2
|
Annual Production | 3,000
ton
|
Production Hrs. Annual | 2,210
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $288,658 | 1,877,280 |
kWh
|
$0.15 | |
Natural Gas | $99,484 | 15,860 |
MMBtu
|
$6.27 | |
Waste Disposal Costs | |||||
Water Usage | $39,056 | 16,061 |
Tgal
|
$2.43 | |
Water Disposal | $30,608 | 12,551 |
Tgal
|
$2.44 | |
TOTAL YEARLY COSTS | $457,806 | ||||
RECOMMENDED SAVINGS* | $85,204 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Personnel Changes Savings | Primary Raw Material Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $17,942 | - |
$19,142
59,687
kWh
|
- | $(-1,200.0) | - | |
02 | 2.1233: Analyze flue gas for proper air/fuel ratio | $488 | - | - |
$1,688
-
MMBtu
|
$(-1,200.0) | - | |
03 | 2.4231: Reduce the pressure of compressed air to the minimum required | $3,255 | $300 |
$3,255
10,153
kWh
|
- | - | - | |
04 | 2.4235: Remove or close off unneeded compressed air lines | $5,523 | $1,537 |
$5,523
17,222
kWh
|
- | - | - | |
05 | 2.2511: Insulate bare equipment | $7,711 | $3,227 | - |
$7,711
-
MMBtu
|
- | - | |
06 | 2.7224: Reduce space conditioning during non-working hours | $2,550 | $1,334 |
$2,550
7,952
kWh
|
- | - | - | |
07 | 2.2135: Repair and eliminate steam leaks | $2,960 | $2,345 | - |
$2,960
-
MMBtu
|
- | - | |
08 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $202 | $192 |
$202
631
kWh
|
- | - | - | |
09 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $17,582 | $23,946 |
$17,582
54,826
kWh
|
- | - | - | |
10 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $26,991 | $61,830 |
$25,653
79,992
kWh
|
- | $1,202 | $136 | |
TOTAL RECOMMENDED | $85,204 | $94,711 |
$73,907
230,463
kWh
|
$12,359
-
MMBtu
|
$(-1,198.0) | $136 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Personnel Changes Savings | Primary Raw Material Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs