ITAC Assessment: SF0565
ITAC logo
ITAC Assessment: SF0565
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2021
Principal Product medical & hemostasis devices
NAICS 339112: Surgical and Medical Instrument Manufacturing
SIC 3841: Surgical and Medical Instruments and Apparatus
Sales Range $10
M
to 50
M
# of Employees 175
Plant Area 80,000
ft2
Annual Production 1,300,000
units
Production Hrs. Annual 6,370
hrs
Location (State) California

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $277,111 2,327,386
kWh
Electricity Demand $92,643 3,795
kW-mo/yr
Electricity Fees $118,764 -
Natural Gas $28,627 2,065
MMBtu
TOTAL YEARLY COSTS $517,145
RECOMMENDED SAVINGS* $46,554 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $37,558

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Natural Gas Savings
01 2.7224: Reduce space conditioning during non-working hours $770 - $770
4,354
kWh
- - -
02 2.7229: Air condition only space necessary $35,739 $5,236 $21,328
120,633
kWh
- - $14,411
-
MMBtu
03 2.7221: Lower temperature during the winter season and vice-versa $6,884 $1,122 $6,884
38,938
kWh
- - -
04 2.7144: Install spectral reflectors / delamp $603 $135 $502
2,838
kWh
$101
-
kW-mo/yr
- -
05 2.4239: Eliminate or reduce compressed air usage $294 $90 $294
1,661
kWh
- - -
06 2.3132: Recharge batteries on during off-peak demand periods $1,819 $622 - $1,190
-
kW-mo/yr
$629 -
07 2.7243: Improve air circulation with destratification fans / other methods $445 $3,212 $198
1,122
kWh
$247
-
kW-mo/yr
- -
TOTAL RECOMMENDED $46,554 $10,417 $29,976
169,546
kWh
$1,538
-
kW-mo/yr
$629 $14,411
-
MMBtu
TOTAL IMPLEMENTED $37,558 $5,858 $21,328
120,633
kWh
$1,190
-
kW-mo/yr
$629 $14,411
-
MMBtu
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs