Assessment Year | 2021 |
---|---|
Principal Product | Sparkling and Still Wines |
NAICS | 312130: Wineries |
SIC | 2084: Wines, Brandy, and Brandy Spirits |
Sales Range | $5 M to 10M |
# of Employees | 140 |
Plant Area |
43,265
ft2
|
Annual Production | 80,000
units
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $148,614 | 665,482 |
kWh
|
$0.22 |
Electricity Fees | $21,627 | - |
|
- |
LPG | $27,730 | 1,595 |
MMBtu
|
$17.39 |
TOTAL YEARLY COSTS | $197,971 | |||
RECOMMENDED SAVINGS* | $25,483 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $22,798 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | LPG Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|
01 | 2.4231: Reduce the pressure of compressed air to the minimum required | $2,685 | $200 |
$2,685
10,119
kWh
|
- | - | |
02 | 2.2511: Insulate bare equipment | $339 | $227 | - |
$339
-
MMBtu
|
- | |
03 | 2.4239: Eliminate or reduce compressed air usage | $2,582 | $2,866 |
$2,582
9,731
kWh
|
- | - | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $8,879 | $17,947 |
$8,616
32,476
kWh
|
- | $263 | |
05 | 2.4322: Use or replace with energy efficient substitutes | $10,998 | $71,975 |
$10,998
41,455
kWh
|
- | - | |
TOTAL RECOMMENDED | $25,483 | $93,215 |
$24,881
93,781
kWh
|
$339
-
MMBtu
|
$263 | ||
TOTAL IMPLEMENTED | $22,798 | $93,015 |
$22,196
83,662
kWh
|
$339
-
MMBtu
|
$263 |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs