Assessment Year | 2020 |
---|---|
Principal Product | Custom Thin Film Coatings |
NAICS | 334413: Semiconductor and Related Device Manufacturing |
SIC | 3674: Semiconductors and Related Devices |
Sales Range | $1 M to 5M |
# of Employees | 20 |
Plant Area |
9,000
ft2
|
Annual Production | 5,000
units
|
Production Hrs. Annual | 3,000
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $135,505 | 810,718 |
kWh
|
$0.17 | |
Natural Gas | $529 | 35 |
MMBtu
|
$15.16 | |
Waste Disposal Costs | |||||
Water Usage | $2,560 | 128 |
Tgal
|
$20.00 | |
TOTAL YEARLY COSTS | $138,594 | ||||
RECOMMENDED SAVINGS* | $51,415 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | $33,489 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Other Liquid (non-haz) Savings | Personnel Changes Savings | Primary Product Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,246 | $70 |
$1,246
7,460
kWh
|
- | - | - | |
02 | 2.2614: Use cooling tower or economizer to replace chiller cooling | $16,680 | $26,850 |
$16,680
99,823
kWh
|
- | - | - | |
03 | 2.7135: Install occupancy sensors | $4,726 | $14,983 |
$4,536
27,145
kWh
|
- | $132 | $58 | |
04 | 3.1191: Change procedures / equipment / operating conditions | $13,118 | $45,851 |
$(-2,382.0)
(-14,256)
kWh
|
$15,500
-
gal
|
- | - | |
05 | 2.9114: Use solar heat to make electricty | $15,645 | $78,611 |
$15,645
93,625
kWh
|
- | - | - | |
TOTAL RECOMMENDED | $51,415 | $166,365 |
$35,725
213,797
kWh
|
$15,500
-
gal
|
$132 | $58 | ||
TOTAL IMPLEMENTED | $33,489 | $139,445 |
$17,799
106,514
kWh
|
$15,500
-
gal
|
$132 | $58 |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs