Assessment Year | 2020 |
---|---|
Principal Product | Fermented Foods |
NAICS | 311421: Fruit and Vegetable Canning |
SIC | 2035: Pickled Fruits and Vegetables, Vegetable Sauces and Seasonings, and Salad Dressings |
Sales Range | $10 M to 50M |
# of Employees | 80 |
Plant Area |
30,000
ft2
|
Annual Production | 5,000,000
units
|
Production Hrs. Annual | 2,080
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $68,986 | 606,628 |
kWh
|
$0.11 | |
Electricity Demand | $57,937 | 1,715 |
kW-mo/yr
|
$33.78 | |
Natural Gas | $18,262 | 1,537 |
MMBtu
|
$11.88 | |
Waste Disposal Costs | |||||
Water Usage | $106,158 | 5,247 |
Tgal
|
$20.23 | |
TOTAL YEARLY COSTS | $251,343 | ||||
RECOMMENDED SAVINGS* | $157,265 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | $39,726 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Usage Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $4,719 | - |
$5,799
50,977
kWh
|
- | - | - | $(-1,080.0) | - | |
02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,182 | $120 |
$840
7,389
kWh
|
$342
-
kW-mo/yr
|
- | - | - | - | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $11,204 | $25,635 |
$4,818
42,364
kWh
|
$5,568
-
kW-mo/yr
|
- | - | $651 | $167 | |
04 | 2.4231: Reduce the pressure of compressed air to the minimum required | $475 | $1,214 |
$475
4,180
kWh
|
- | - | - | - | - | |
05 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $5,119 | $19,959 |
$5,119
45,014
kWh
|
- | - | - | - | - | |
06 | 2.4231: Reduce the pressure of compressed air to the minimum required | $403 | $1,776 |
$403
3,521
kWh
|
- | - | - | - | - | |
07 | 2.9114: Use solar heat to make electricty | $67,154 | $343,660 |
$44,156
388,287
kWh
|
$22,998
-
kW-mo/yr
|
- | - | - | - | |
08 | 3.1223: Use fog nozzles / spray rinsing instead of immersion rinsing | $22,925 | $1,810 | - | - |
$5,995
-
MMBtu
|
$16,930
-
Tgal
|
- | - | |
09 | 3.1222: Reduce water use with counter current rinsing | $44,084 | $48,094 | - | - |
$3,378
-
MMBtu
|
$9,506
-
Tgal
|
$31,200 | - | |
TOTAL RECOMMENDED | $157,265 | $442,268 |
$61,610
541,732
kWh
|
$28,908
-
kW-mo/yr
|
$9,373
-
MMBtu
|
$26,436
-
Tgal
|
$30,771 | $167 | ||
TOTAL IMPLEMENTED | $39,726 | $30,435 |
$11,495
101,042
kWh
|
$5,568
-
kW-mo/yr
|
$5,995
-
MMBtu
|
$16,930
-
Tgal
|
$(-429.0) | $167 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Usage Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs