| Assessment Year | 2019 |
|---|---|
| Principal Product | Treated Water |
| NAICS | 221310: Water Supply and Irrigation Systems |
| SIC | 4941: Water Supply |
| Sales Range | less than $500 k |
| # of Employees | 24 |
| Plant Area |
35,000
ft2
|
| Annual Production | 830,000
Tgal
|
| Production Hrs. Annual | 8,760
hrs
|
| Location (State) | California |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $161,252 | 1,495,796 |
kWh
|
$0.11 |
| Electricity Demand | $237,141 | 17,505 |
kW-mo/yr
|
$13.55 |
| TOTAL YEARLY COSTS | $398,393 | |||
| RECOMMENDED SAVINGS* | $133,466 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $7,147 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $1,886 | - | - | - | $1,886 | - | - | |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $5,261 | $16,688 |
$4,861
41,377
kWh
|
- | - | $475 | $(-75.0) | |
| 03 | 2.4324: Replace hydraulic / pneumatic equipment with electric equipment | $47,766 | $327,497 |
$47,766
473,684
kWh
|
- | - | - | - | |
| 04 | 2.9114: Use solar heat to make electricty | $78,553 | $677,569 |
$64,976
538,746
kWh
|
$13,577
-
kW-mo/yr
|
- | - | - | |
| TOTAL RECOMMENDED | $133,466 | $1,021,754 |
$117,603
1,053,807
kWh
|
$13,577
-
kW-mo/yr
|
$1,886 | $475 | $(-75.0) | ||
| TOTAL IMPLEMENTED | $7,147 | $16,688 |
$4,861
41,377
kWh
|
- | $1,886 | $475 | $(-75.0) | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs