Assessment Year | 2019 |
---|---|
Principal Product | Metal Parts |
NAICS | 332710: Machine Shops |
SIC | 3599: Industrial and Commercial Machinery and Equipment, Not Elsewhere Classified |
Sales Range | $1 M to 5M |
# of Employees | 20 |
Plant Area |
10,000
ft2
|
Annual Production | 120,000
units
|
Production Hrs. Annual | 3,250
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $53,000 | 329,310 |
kWh
|
$0.16 |
Electricity Demand | $20,081 | 1,320 |
kW-mo/yr
|
$15.21 |
Natural Gas | $1,825 | 141 |
MMBtu
|
$12.94 |
TOTAL YEARLY COSTS | $74,906 | |||
RECOMMENDED SAVINGS* | $26,673 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $26,332 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,145 | - |
$3,465
21,529
kWh
|
- | $(-1,320.0) | - | |
02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $341 | $220 |
$302
1,878
kWh
|
$39
-
kW-mo/yr
|
- | - | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,832 | $7,129 |
$2,525
15,650
kWh
|
$893
-
kW-mo/yr
|
$442 | $(-28.0) | |
04 | 2.9114: Use solar heat to make electricty | $20,355 | $80,550 |
$17,127
106,420
kWh
|
$3,228
-
kW-mo/yr
|
- | - | |
TOTAL RECOMMENDED | $26,673 | $87,899 |
$23,419
145,477
kWh
|
$4,160
-
kW-mo/yr
|
$(-878.0) | $(-28.0) | ||
TOTAL IMPLEMENTED | $26,332 | $87,679 |
$23,117
143,599
kWh
|
$4,121
-
kW-mo/yr
|
$(-878.0) | $(-28.0) |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs