Assessment Year | 2017 |
---|---|
Principal Product | electronic medical devices |
NAICS | 334510: Electromedical and Electrotherapeutic Apparatus Manufacturing |
SIC | 3845: Electromedical and Electrotherapeutic Apparatus |
Sales Range | $10 M to 50M |
# of Employees | 110 |
Plant Area |
65,000
ft2
|
Annual Production | 5,000
units
|
Production Hrs. Annual | 3,250
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $116,615 | 789,123 |
kWh
|
$0.15 |
Electricity Demand | $30,405 | 2,207 |
kW-mo/yr
|
$13.78 |
Natural Gas | $42,469 | 4,222 |
MMBtu
|
$10.06 |
TOTAL YEARLY COSTS | $189,489 | |||
RECOMMENDED SAVINGS* | $83,375 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $2,768 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,032 | $100 |
$769
5,217
kWh
|
$263
-
kW-mo/yr
|
|
02 | 2.7111: Reduce illumination to minimum necessary levels | $6,259 | $2,279 |
$4,699
31,870
kWh
|
$1,560
-
kW-mo/yr
|
|
03 | 2.7135: Install occupancy sensors | $1,736 | $7,335 |
$1,231
8,351
kWh
|
$505
-
kW-mo/yr
|
|
04 | 2.9114: Use solar heat to make electricty | $74,348 | $373,319 |
$58,731
398,362
kWh
|
$15,617
-
kW-mo/yr
|
|
TOTAL RECOMMENDED | $83,375 | $383,033 |
$65,430
443,800
kWh
|
$17,945
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | $2,768 | $7,435 |
$2,000
13,568
kWh
|
$768
-
kW-mo/yr
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs