Assessment Year | 2016 |
---|---|
Principal Product | Wine |
NAICS | 312130: Wineries |
SIC | 2084: Wines, Brandy, and Brandy Spirits |
Sales Range | $10 M to 50M |
# of Employees | 113 |
Plant Area |
180,000
ft2
|
Annual Production | 659,000
units
|
Production Hrs. Annual | 4,389
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $342,846 | 2,065,237 |
kWh
|
$0.17 |
Natural Gas | $37,918 | 3,811 |
MMBtu
|
$9.95 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $287,291 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $285,763 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Primary Raw Material Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,727 | - |
$3,407
20,521
kWh
|
- | - | $(-1,680.0) | - | |
02 | 2.3137: Use power during off-peak periods | $1,528 | - |
$11
261
kWh
|
$1,517
-
kW-mo/yr
|
- | - | - | |
03 | 2.7224: Reduce space conditioning during non-working hours | $22,945 | - |
$7,244
43,635
kWh
|
- |
$15,701
-
MMBtu
|
- | - | |
04 | 2.2694: Use highest temperature for chilling or cold storage | $15,446 | $7,297 |
$15,446
93,040
kWh
|
- | - | - | - | |
05 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $6,250 | $2,903 |
$6,250
35,650
kWh
|
- | - | - | - | |
06 | 2.2621: Modify refrigeration system to operate at a lower pressure | $57,609 | $52,742 |
$57,609
347,016
kWh
|
- | - | - | - | |
07 | 2.4322: Use or replace with energy efficient substitutes | $47,178 | $102,267 |
$47,178
284,188
kWh
|
- | - | - | - | |
08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,956 | $17,949 |
$4,134
24,902
kWh
|
- | - | $578 | $244 | |
09 | 2.2511: Insulate bare equipment | $6,631 | $26,784 |
$6,631
39,945
kWh
|
- | - | - | - | |
10 | 2.7135: Install occupancy sensors | $3,368 | $13,975 |
$3,368
20,288
kWh
|
- | - | - | - | |
11 | 2.9114: Use solar heat to make electricty | $119,653 | $1,013,583 |
$119,653
720,756
kWh
|
- | - | - | - | |
TOTAL RECOMMENDED | $287,291 | $1,237,500 |
$270,931
1,630,202
kWh
|
$1,517
-
kW-mo/yr
|
$15,701
-
MMBtu
|
$(-1,102.0) | $244 | ||
TOTAL IMPLEMENTED | $285,763 | $1,237,500 |
$270,920
1,629,941
kWh
|
- |
$15,701
-
MMBtu
|
$(-1,102.0) | $244 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Primary Raw Material Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs