Assessment Year | 2015 |
---|---|
Principal Product | Inflatable Boats |
NAICS | 326199: All Other Plastics Product Manufacturing |
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $500 k to 1M |
# of Employees | 117 |
Plant Area |
78,092
ft2
|
Annual Production | 1,300
pieces
|
Production Hrs. Annual | 4,992
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $84,192 | 562,560 |
kWh
|
$0.15 |
Electricity Demand | $20,337 | 1,953 |
kW-mo/yr
|
$10.41 |
LPG | $8,632 | 378 |
MMBtu
|
$22.85 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $20,863 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $15,080 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $2,904 | - |
$2,904
19,404
kWh
|
- | - | - | |
02 | 2.2135: Repair and eliminate steam leaks | $1,344 | $648 |
$1,344
8,978
kWh
|
- | - | - | |
03 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,965 | $3,081 |
$1,965
11,331
kWh
|
- | - | - | |
04 | 2.7133: Use separate switches on perimeter lighting which may be turned off when natural light is available | $914 | $1,510 |
$718
4,797
kWh
|
$196
-
kW-mo/yr
|
- | - | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $13,736 | $26,646 |
$11,787
78,756
kWh
|
$2,538
-
kW-mo/yr
|
$401 | $(-990.0) | |
TOTAL RECOMMENDED | $20,863 | $31,885 |
$18,718
123,266
kWh
|
$2,734
-
kW-mo/yr
|
$401 | $(-990.0) | ||
TOTAL IMPLEMENTED | $15,080 | $27,294 |
$13,131
87,734
kWh
|
$2,538
-
kW-mo/yr
|
$401 | $(-990.0) |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs