Assessment Year | 2014 |
---|---|
Principal Product | Ophthalmic Equipment |
NAICS | 333314: Optical Instrument and Lens Manufacturing |
SIC | 3827: Optical Instruments and Lenses |
Sales Range | $10 M to 50M |
# of Employees | 720 |
Plant Area |
200,000
ft2
|
Annual Production | 5
units
|
Production Hrs. Annual | 2,600
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $188,873 | 2,524,403 |
kWh
|
$0.075 |
Electricity Demand | $104,412 | 5,851 |
kW-mo/yr
|
$17.85 |
Natural Gas | $20,517 | 2,317 |
MMBtu
|
$8.86 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $56,008 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $13,290 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings |
---|---|---|---|---|---|---|---|
01 | 2.7144: Install spectral reflectors / delamp | $660 | $280 |
$398
3,177
kWh
|
$262
-
kW-mo/yr
|
- | |
02 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $10,804 | $9,262 |
$3,549
28,314
kWh
|
$8,354
-
kW-mo/yr
|
$(-1,099.0) | |
03 | 2.6211: Conserve energy by efficient use of vending machines | $317 | $307 |
$317
2,529
kWh
|
- | - | |
04 | 2.7226: Use computer programs to optimize hvac performance | $28,600 | $42,672 |
$18,248
145,564
kWh
|
$10,352
-
kW-mo/yr
|
- | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $12,630 | $27,842 |
$3,274
26,114
kWh
|
- | $9,356 | |
06 | 2.7135: Install occupancy sensors | $2,997 | $14,024 |
$1,819
14,511
kWh
|
$1,178
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $56,008 | $94,387 |
$27,605
220,209
kWh
|
$20,146
-
kW-mo/yr
|
$8,257 | ||
TOTAL IMPLEMENTED | $13,290 | $28,122 |
$3,672
29,291
kWh
|
$262
-
kW-mo/yr
|
$9,356 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs