| Assessment Year | 2011 |
|---|---|
| Principal Product | Chocolate |
| NAICS | 311352: Confectionery Manufacturing from Purchased Chocolate |
| SIC | 2026: Fluid Milk |
| Sales Range | $10 M to 50M |
| # of Employees | 125 |
| Plant Area |
80,000
ft2
|
| Annual Production | 20,000,000
units
|
| Production Hrs. Annual | 3,536
hrs
|
| Location (State) | Hawaii |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $225,745 | 1,313,544 |
kWh
|
$0.17 |
| Electricity Demand | $33,364 | 4,008 |
kW-mo/yr
|
$8.32 |
| Electricity Fees | $4,106 | - |
|
- |
| LPG | $22,755 | 634 |
MMBtu
|
$35.89 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $25,132 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $23,130 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Primary Raw Material Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,204 | $73 |
$1,204
5,350
kWh
|
- | - | - | |
| 02 | 2.7132: Install timers on light switches in little used areas | $439 | $235 |
$439
2,001
kWh
|
- | - | - | |
| 03 | 2.3212: Optimize plant power factor | $2,952 | $3,821 | - | - | $2,952 | - | |
| 04 | 2.4131: Size electric motors for peak operating efficiency | $2,879 | $3,638 |
$2,879
12,787
kWh
|
- | - | - | |
| 05 | 2.7135: Install occupancy sensors | $7,621 | $11,002 |
$7,621
33,728
kWh
|
- | - | - | |
| 06 | 2.4131: Size electric motors for peak operating efficiency | $7,794 | $20,780 |
$7,794
39,582
kWh
|
- | - | - | |
| 07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $241 | $700 |
$104
527
kWh
|
$6
-
kW-mo/yr
|
- | $131 | |
| 08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,002 | $12,392 |
$2,002
7,795
kWh
|
- | - | - | |
| TOTAL RECOMMENDED | $25,132 | $52,641 |
$22,043
101,770
kWh
|
$6
-
kW-mo/yr
|
$2,952 | $131 | ||
| TOTAL IMPLEMENTED | $23,130 | $40,249 |
$20,041
93,975
kWh
|
$6
-
kW-mo/yr
|
$2,952 | $131 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Primary Raw Material Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs