Assessment Year | 2008 |
---|---|
Principal Product | Bottled wine |
NAICS | 312130: Wineries |
SIC | 2084: Wines, Brandy, and Brandy Spirits |
Sales Range | $10 M to 50M |
# of Employees | 77 |
Plant Area |
120,000
ft2
|
Annual Production | 300,000
units
|
Production Hrs. Annual | 4,368
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $241,017 | 2,768,977 |
kWh
|
$0.087 |
Electricity Demand | $85 | 7,499 |
kW-mo/yr
|
$0.011 |
Electricity Fees | $11,841 | - |
|
- |
Natural Gas | $64,484 | 5,854 |
MMBtu
|
$11.02 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $168,879 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $99,551 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.6231: Utilize controls to operate equipment only when needed | $9,294 | $2,185 |
$6,479
72,592
kWh
|
$2,815
-
kW-mo/yr
|
- | |
02 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $2,063 | $1,355 |
$2,063
23,115
kWh
|
- | - | |
03 | 2.7135: Install occupancy sensors | $2,458 | $2,016 |
$1,105
12,378
kWh
|
$1,353
-
kW-mo/yr
|
- | |
04 | 2.2621: Modify refrigeration system to operate at a lower pressure | $45,262 | $60,000 |
$33,122
354,757
kWh
|
$12,140
-
kW-mo/yr
|
- | |
05 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $1,324 | $2,426 |
$1,324
14,838
kWh
|
- | - | |
06 | 2.2437: Recover waste heat from equipment | $9,259 | $18,610 | - | - |
$9,259
-
MMBtu
|
|
07 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $853 | $1,675 |
$853
9,561
kWh
|
- | - | |
08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $89,877 | $118,644 |
$75,000
840,336
kWh
|
$14,877
-
kW-mo/yr
|
- | |
09 | 2.4322: Use or replace with energy efficient substitutes | $4,960 | $24,943 |
$3,946
44,217
kWh
|
$1,014
-
kW-mo/yr
|
- | |
10 | 2.2437: Recover waste heat from equipment | $1,273 | $11,479 |
$542
6,079
kWh
|
- |
$731
-
MMBtu
|
|
11 | 2.2511: Insulate bare equipment | $2,256 | $22,235 |
$2,256
25,276
kWh
|
- | - | |
TOTAL RECOMMENDED | $168,879 | $265,568 |
$126,690
1,403,149
kWh
|
$32,199
-
kW-mo/yr
|
$9,990
-
MMBtu
|
||
TOTAL IMPLEMENTED | $99,551 | $167,838 |
$82,307
922,207
kWh
|
$17,244
-
kW-mo/yr
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs