Assessment Year | 2008 |
---|---|
Principal Product | Coffee and teas |
NAICS | 311920: Coffee and Tea Manufacturing |
SIC | 2095: Roasted Coffee |
Sales Range | $10 M to 50M |
# of Employees | 95 |
Plant Area |
50,000
ft2
|
Annual Production | 8,000,000
lb
|
Production Hrs. Annual | 3,120
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $75,676 | 546,733 |
kWh
|
$0.14 |
Electricity Demand | $13,220 | 1,687 |
kW-mo/yr
|
$7.84 |
Electricity Fees | $7,328 | - |
|
- |
Natural Gas | $62,138 | 5,312 |
MMBtu
|
$11.70 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $11,699 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.7134: Use photocell controls | $651 | $664 |
$455
3,286
kWh
|
$196
-
kW-mo/yr
|
|
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,436 | $3,094 |
$2,075
14,984
kWh
|
$361
-
kW-mo/yr
|
|
03 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $1,354 | $1,767 |
$1,354
9,773
kWh
|
- | |
04 | 2.7135: Install occupancy sensors | $405 | $738 |
$319
2,303
kWh
|
$86
-
kW-mo/yr
|
|
05 | 2.4322: Use or replace with energy efficient substitutes | $5,195 | $21,950 |
$5,195
37,506
kWh
|
- | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,658 | $9,606 |
$1,321
9,538
kWh
|
$337
-
kW-mo/yr
|
|
TOTAL RECOMMENDED | $11,699 | $37,819 |
$10,719
77,390
kWh
|
$980
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs