Assessment Year | 2006 |
---|---|
Principal Product | Chocolate |
NAICS | 311351: Chocolate and Confectionery Manufacturing from Cacao Beans |
SIC | 2066: Chocolate and Cocoa Products |
Sales Range | $100 M to 500M |
# of Employees | 200 |
Plant Area |
600,000
ft2
|
Annual Production | 15,000,000
lb
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $1,558,332 | 38,653,492 |
kWh
|
$0.040 |
Electricity Demand | $944,276 | 77,826 |
kW-mo/yr
|
$12.13 |
Natural Gas | $4,693,182 | 412,864 |
MMBtu
|
$11.37 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $54,463 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $1,017 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,017 | - |
$1,017
39,626
kWh
|
- | - | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,235 | $117 |
$1,235
30,630
kWh
|
- | - | |
03 | 2.1321: Replace fossil fuel equipment with electrical equipment | $5,332 | $3,710 | - | - |
$5,332
-
MMBtu
|
|
04 | 2.4133: Use most efficient type of electric motors | $17,266 | $20,534 |
$10,730
266,134
kWh
|
$6,536
-
kW-mo/yr
|
- | |
05 | 2.7135: Install occupancy sensors | $2,860 | $4,608 |
$1,588
39,394
kWh
|
$1,272
-
kW-mo/yr
|
- | |
06 | 2.7134: Use photocell controls | $14,161 | $39,154 |
$8,188
203,085
kWh
|
$5,973
-
kW-mo/yr
|
- | |
07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $10,694 | $33,264 |
$6,446
159,870
kWh
|
$4,248
-
kW-mo/yr
|
- | |
08 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,898 | $7,608 |
$1,043
25,885
kWh
|
$855
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $54,463 | $108,995 |
$30,247
764,624
kWh
|
$18,884
-
kW-mo/yr
|
$5,332
-
MMBtu
|
||
TOTAL IMPLEMENTED | $1,017 | - |
$1,017
39,626
kWh
|
- | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs