ITAC Assessment: SF0328
ITAC logo
ITAC Assessment: SF0328
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2006
Principal Product Cattle Supplement Feed
NAICS 311119: Other Animal Food Manufacturing
SIC 2048: Prepared Feed and Feed Ingredients for Animals and Fowls, Except Dogs and Cats
Sales Range $5
M
to 10
M
# of Employees 20
Plant Area 200,000
ft2
Annual Production 10,000
units
Production Hrs. Annual 5,472
hrs
Location (State) California

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $41,989 333,648
kWh
Electricity Demand $6,449 1,237
kW-mo/yr
Natural Gas $225,594 20,237
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $14,852 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $12,011

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
01 2.2135: Repair and eliminate steam leaks $4,864 - - - $4,864
-
MMBtu
02 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $1,420 - $1,420
13,534
kWh
- -
03 2.1241: Reduce excessive boiler blowdown $2,038 $473 - - $2,038
-
MMBtu
04 2.2511: Insulate bare equipment $2,821 $783 - - $2,821
-
MMBtu
05 2.4111: Utilize energy-efficient belts and other improved mechanisms $522 $298 $448
3,713
kWh
$74
-
kW-mo/yr
-
06 2.7142: Utilize higher efficiency lamps and/or ballasts $2,841 $2,360 $2,356
19,494
kWh
$485
-
kW-mo/yr
-
07 2.4133: Use most efficient type of electric motors $346 $273 $301
2,488
kWh
$45
-
kW-mo/yr
-
TOTAL RECOMMENDED $14,852 $4,187 $4,525
39,229
kWh
$604
-
kW-mo/yr
$9,723
-
MMBtu
TOTAL IMPLEMENTED $12,011 $1,827 $2,169
19,735
kWh
$119
-
kW-mo/yr
$9,723
-
MMBtu
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs