| Assessment Year | 2003 |
|---|---|
| Principal Product | Beef jerky |
| NAICS | 311612: Meat Processed from Carcasses |
| SIC | 2013: Sausages and Other Prepared Meat Products |
| Sales Range | $50 M to 100M |
| # of Employees | 150 |
| Plant Area |
45,000
ft2
|
| Annual Production | 75,000,000
lb
|
| Production Hrs. Annual | 8,400
hrs
|
| Location (State) | California |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $292,692 | 2,742,800 |
kWh
|
$0.11 |
| Electricity Demand | $61,186 | 5,524 |
kW-mo/yr
|
$11.08 |
| Natural Gas | $146,619 | 23,656 |
MMBtu
|
$6.20 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $31,578 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 3.7312: Implement a regular maintenance program to reduce emissions from leaky valves and pipe fittings | $486 | - |
$486
7,357
kWh
|
- | - | - | |
| 02 | 2.7132: Install timers on light switches in little used areas | $425 | $175 |
$359
3,360
kWh
|
$66
-
kW-mo/yr
|
- | - | |
| 03 | 2.2621: Modify refrigeration system to operate at a lower pressure | $19,165 | $10,225 |
$17,957
168,120
kWh
|
$1,208
-
kW-mo/yr
|
- | - | |
| 04 | 2.4221: Install compressor air intakes in coolest locations | $1,663 | $1,080 |
$1,436
14,380
kWh
|
$227
-
kW-mo/yr
|
- | - | |
| 05 | 2.4231: Reduce the pressure of compressed air to the minimum required | $3,955 | $2,574 |
$3,445
32,256
kWh
|
$510
-
kW-mo/yr
|
- | - | |
| 06 | 2.7145: Install skylights | $2,077 | $1,440 |
$1,800
16,850
kWh
|
$277
-
kW-mo/yr
|
- | - | |
| 07 | 2.2123: Insulate feedwater tank | $527 | $1,186 | - | - |
$527
-
MMBtu
|
- | |
| 08 | 3.5217: Reuse / recycle/ sell paper products | $3,280 | $800 | - | - | - | $3,280 | |
| TOTAL RECOMMENDED | $31,578 | $17,480 |
$25,483
242,323
kWh
|
$2,288
-
kW-mo/yr
|
$527
-
MMBtu
|
$3,280 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | ||