Assessment Year | 2003 |
---|---|
Principal Product | Radio Assembly |
NAICS | 334220: Radio and Television Broadcasting and Wireless Communications Equipment Manufacturing |
SIC | 3663: Radio and Television Broadcasting and Communications Equipment |
Sales Range | $10 M to 50M |
# of Employees | 140 |
Plant Area |
42,000
ft2
|
Annual Production | 0
units
|
Production Hrs. Annual | 4,992
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $89,723 | 887,317 |
kWh
|
$0.10 |
Electricity Demand | $24,279 | 1,880 |
kW-mo/yr
|
$12.91 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $13,827 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings |
---|---|---|---|---|---|---|---|
01 | 2.7111: Reduce illumination to minimum necessary levels | $6,136 | - | n/a |
$4,694
46,426
kWh
|
$1,442
-
kW-mo/yr
|
- |
02 | 2.4224: Upgrade controls on compressors | $1,100 | $188 | n/a |
$1,100
10,885
kWh
|
- | - |
03 | 2.7135: Install occupancy sensors | $376 | $388 | n/a |
$288
2,845
kWh
|
$88
-
kW-mo/yr
|
- |
04 | 3.6193: Install equipment (eg compactor) to reduce disposal costs | $3,415 | $9,181 | n/a | - | - |
$3,415
-
lb
|
05 | 3.5217: Reuse / recycle/ sell paper products | $2,800 | $9,550 | n/a | - | - |
$2,800
-
lb
|
TOTAL RECOMMENDED | $13,827 | $19,307 |
$6,082
60,156
kWh
|
$1,530
-
kW-mo/yr
|
$6,215
-
lb
|
||
TOTAL IMPLEMENTED | - | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs